Insulated Metal Panels
Horizon Wall Panels - Smooth
Horizon Wall Panels - Embossed
Horizon Wall - Mesa Smooth panels are produced with a standard Mesa profiled smooth steel face. These panels are an economical option for industrial and commercial walls, with added strength.
- Coverage Width: 42” (1067mm).
- Panel Lengths: 8’ to 52’ (2438mm to 15850mm).
- Exterior Face: 22ga, 24ga, or 26ga Mesa Smooth galvanized G-90 (Z275) pre painted steel.
- Interior Face: 22ga, 24ga, or 26ga Mesa profile in Smooth or Light Embossed finish galvanized G-90 (Z275) pre painted steel in Regal White. Other colour options may be available.
THICKNESS | 2” | 3” | 4” | 5” | 6” |
---|---|---|---|---|---|
R-VALUE* | 16.67 | 25 | 33.33 | 41.67 | 50 |
Horizon Wall - Mesa Light Embossed panels are produced with a standard Mesa profiled Light Embossed steel face. These panels are an economical option for industrial and commercial walls, with added strength from a double Mesa profile for long panel lengths.
- Coverage Width: 42” (1067mm).
- Panel Lengths: 8’ to 52’ (2438mm to 15850mm).
- Exterior Face: 22ga, 24ga, or 26ga Mesa Light Embossed galvanized G-90 (Z275) pre painted steel
- Interior Face: 22ga, 24ga, or 26ga Mesa profile in Smooth or Light Embossed finish galvanized G-90 (Z275) pre painted steel in Regal White. Other colour options are available.
THICKNESS | 2” | 3” | 4” | 5” | 6” |
---|---|---|---|---|---|
R-VALUE* | 16.67 | 25 | 33.33 | 41.67 | 50 |
Standard Exterior Colours
Premium Exterior Colours
- Colours may not appear exactly as shown above and may vary slightly.
- Please confirm prior to specifying, estimating or ordering.
- Final colour selection should be made from a steel colour sample.
- Colour selection may be subject to availability.
- Custom colours available upon request.
TESTING: INSULATED METAL PANELS
Standard | Description | Results |
---|---|---|
CAN/ULC S101 | Standard Methods of Fire Endurance Tests of Building Construction and Materials | 15-minute stay in place |
CAN/ULC S102 | Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies | Flame Spread < 25, Smoke Development < 200 |
CAN/ULC S126 | Standard Method of Test for Fire Spread Under Roof-Deck Assemblies | Complies |
CAN/ULC S127 | Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials | Flame Spread < 350 foam core w/o steel skin |
CAN/ULC S138 | Standard Method of Test for Fire Growth of Insulated Building Metal Panels in a Full-Scale Room Configuration | Complies |
ASTM E84 | Standard Test Method for Surface Burning Characteristics of Building Materials | Flame Spread < 25, Smoke Development < 200 |
NFPA 286 | Standard Methods of Fire Tests for Evaluating Contribution for Wall and Ceiling Interior Finish to Room Fire Growth | Complies |
ASTM E72 | Standard Test Methods of Conducting Strength Tests of Panels for Building Construction | See Load Charts for load/span and deflection tables |
ASTM E1592 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference | See Load Charts |
ASTM E1646 | Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems | No water penetration at 20 psf pressure differential |
ASTM E1680 | Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems | 0.02 L/(s.m2) at 75 Pa (0.004 cfm/ft2 at 1.57 psf) |
ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | 0.02 L/(s.m2) at 75 Pa (0.004 cfm/ft2 at 1.57 psf) |
ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | No water penetration at 20 psf pressure differential |
ASTM C518 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | K-Factor of 0.136 BTU.in/hr.ft2. °F at 75°F |
ASTM C1363 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus | K-Factor of 0.12 BTU.in/ hr.ft2. °F at 39°F |
WALL LOAD SPAN TABLES
- PRODUCT: Insulated Wall Panel
- PROFILE: Mesa or Smooth
- SERIES: Edge, Horizon
- GAUGE: 26ga or heavier
- FINISHED: Embossed or Smooth
Panel Thickness | Design Criteria | PSF | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
4' | 5' | 6' | 7' | 8' | 9' | 10' | 11' | 12' | 13' | 14' | ||
2" Thick (See Table Note #3) | Bending/Shear | 93 | 59 | 41 | 30 | 23 | 18 | 15 | 12 | 10 | ||
Deflection (L/180) | 47 | 41 | 33 | 27 | 22 | 19 | 16 | 14 | 12 | |||
Connection | 42 | 35 | 33 | 26 | 22 | 19 | 16 | 15 | 13 | |||
3" Thick | Bending/Shear | 126 | 101 | 84 | 68 | 52 | 41 | 33 | 27 | 23 | ||
Deflection (L/180) | 94 | 77 | 68 | 58 | 34 | 32 | 29 | 19 | 17 | |||
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | |||
4" Thick | Bending/Shear | 168 | 134 | 112 | 84 | 64 | 51 | 41 | 34 | 29 | 24 | 21 |
Deflection (L/180) | 110 | 101 | 92 | 79 | 67 | 57 | 49 | 42 | 37 | 32 | 29 | |
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | 17 | 16 | |
5" Thick | Bending/Shear | 168 | 134 | 112 | 84 | 64 | 51 | 41 | 34 | 29 | 24 | 21 |
Deflection (L/180) | 110 | 101 | 92 | 79 | 67 | 57 | 49 | 42 | 37 | 32 | 29 | |
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | 17 | 16 | |
6" Thick | Bending/Shear | 168 | 134 | 112 | 84 | 64 | 51 | 41 | 34 | 29 | 24 | 21 |
Deflection (L/180) | 110 | 101 | 92 | 79 | 67 | 57 | 49 | 42 | 37 | 32 | 29 | |
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | 17 | 16 |
TABLE NOTES:
- Allowable loads were derived from tests conducted in accordance with ASTM E1592 and ASTM E72.
- Allowable loads are calculated with a factor of safety of 2.0 for bending and shear.
- Connection strengths reflect a standard fastener pattern - (@) 1/4” - 14 self drilling screw into minimum 14ga substrate. Other substrates must be designed separately. 2” wall panel utilize a flat clip. All other thicknesses utilize an angle clip.
- Fastener capacity is based on manufacturer pullout/pullover data and are calculated with a safety factor of 3.0.
- Allowable loads assume a minimum bearing of 2”.
- Thermal Effects were not considered in analysis.
- The structural capacity of the supporting members were not considered.
- Bending/Shear and Deflection for 5” and 6” panels based on 4” capacity.
PANEL WEIGHTS & LENGTHS TABLE
- Width: 42”
- Profile: Mesa
- Insulation Thickness: 2”, 3”, 4”, 5”, 6”
- Exterior Facing: 22ga, 24ga, 26ga
- Interior Facing: 22ga, 24ga, 26ga
- Available Finish: Light Emboss
Panel Weights (PSF)
Panel Thickness (in.) | Panel Width (in.) | PSF | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
26/26 | 24/26 | 22/26 | 26/24 | 24/24 | 22/24 | 26/22 | 24/22 | 22/22 | ||
2 | 42 | 2.23 | 2.48 | 2.73 | 2.48 | 2.73 | 2.98 | 2.73 | 2.98 | 3.23 |
3 | 42 | 2.44 | 2.69 | 2.94 | 2.69 | 2.94 | 3.19 | 2.94 | 3.19 | 3.44 |
4 | 42 | 2.65 | 2.90 | 3.15 | 2.90 | 3.15 | 3.40 | 3.15 | 3.40 | 3.65 |
5 | 42 | 2.85 | 3.10 | 3.35 | 3.10 | 3.35 | 3.60 | 3.35 | 3.60 | 3.85 |
6 | 42 | 3.06 | 3.31 | 3.56 | 3.31 | 3.56 | 3.81 | 3.56 | 3.81 | 4.06 |
Maximum Length based on colour (ft)
Panel Thickness (in.) | Panel Width (in.) | Edge 22ga Wall* | Horizon 26ga/26ga Wall | Skyline 24ga/26ga Roof | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Light | Medium | Dark | Light | Medium | Dark | Light | Medium | Dark | ||
2 | 42 | 25' | 25' | 20' | 38' | 25' | 16' | 47' | 36' | 24' |
3 | 42 | 30' | 30' | 20' | 45' | 35' | 25' | 50' | 38' | 30' |
4 | 42 | 30' | 30' | 25' | 50' | 38' | 28' | 52' | 41' | 32' |
5 | 42 | 32' | 30' | 25' | 52' | 41' | 30' | 52' | 44' | 34' |
6 | 42 | 32' | 30' | 25' | 52' | 44' | 32' | 52' | 47' | 36' |
*Smooth or Embossed
Light = Regal White
Medium = Sierra Tan, Parchment, Silver Metallic
Dark = All others
Based on 5’ support spacing for walls & 4’ support spacing for roofs
*Smooth or Embossed
Subject to change without notice. Please refer to our website, www.ubuildsb.com for current information.
Edge Wall Panels - Smooth
Edge Wall Panels - Light Embossed
Edge Wall Panels - Heavy Embossed
Leading Edge - Smooth panels are produced with a standard smooth steel face. This provides a flat, smooth face, adding a clean look to the exterior.
- COVERAGE WIDTH: 42” (1067mm)
- PANEL LENGTHS: 8’ TO 32’ (2438mm to 9754mm)
- EXTERIOR FACE: 22ga Flat Smooth galvanized G-90 (Z275) pre painted steel
- INTERIOR FACE: 22ga, 24ga, or 26ga Mesa profile in Smooth or Light Embossed finish galvanized G-90 (Z275) pre painted steel in Regal White. Other colour options may be available.
THICKNESS | 2” | 3” | 4” | 5” | 6” |
---|---|---|---|---|---|
R-VALUE* | 16.67 | 25 | 33.33 | 41.67 | 50 |
Leading Edge Wall - Light Embossed panels are produced with a standard light embossed flat steel face. This provides added subtle visual texture to a flat panel.
- COVERAGE WIDTH: 42” (1067mm)
- PANEL LENGTHS: 8’ TO 32’ (2438mm to 9754mm)
- EXTERIOR FACE: 22ga Flat Light Embossed galvanized G-90 (Z275) pre painted steel
- INTERIOR FACE: 22ga, 24ga, or 26ga Mesa profile in Smooth or Light Embossed galvanized G-90 (Z275) pre painted steel in Regal White. Other colour options are available.
THICKNESS | 2” | 3” | 4” | 5” | 6” |
---|---|---|---|---|---|
R-VALUE* | 16.67 | 25 | 33.33 | 41.67 | 50 |
Test based on ASTM C1363 with 40°F (4.4°C) mean temp with a temp differential of 58°F (14°C).
Standard Colours
Premium Colours
- Colours may not appear exactly as shown above and may vary slightly.
- Please confirm prior to specifying, estimating or ordering.
- Final colour selection should be made from a steel colour sample.
- Colour selection may be subject to availability.
- Custom colours available upon request.
TESTING: INSULATED METAL PANELS
Standard | Description | Results |
---|---|---|
CAN/ULC S101 | Standard Methods of Fire Endurance Tests of Building Construction and Materials | 15-minute stay in place |
CAN/ULC S102 | Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies | Flame Spread < 25, Smoke Development < 200 |
CAN/ULC S126 | Standard Method of Test for Fire Spread Under Roof-Deck Assemblies | Complies |
CAN/ULC S127 | Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials | Flame Spread < 350 foam core w/o steel skin |
CAN/ULC S138 | Standard Method of Test for Fire Growth of Insulated Building Metal Panels in a Full-Scale Room Configuration | Complies |
ASTM E84 | Standard Test Method for Surface Burning Characteristics of Building Materials | Flame Spread < 25, Smoke Development < 200 |
NFPA 286 | Standard Methods of Fire Tests for Evaluating Contribution for Wall and Ceiling Interior Finish to Room Fire Growth | Complies |
ASTM E72 | Standard Test Methods of Conducting Strength Tests of Panels for Building Construction | See Load Charts for load/span and deflection tables |
ASTM E1592 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference | See Load Charts |
ASTM E1646 | Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems | No water penetration at 20 psf pressure differential |
ASTM E1680 | Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems | 0.02 L/(s.m2) at 75 Pa (0.004 cfm/ft2 at 1.57 psf) |
ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | 0.02 L/(s.m2) at 75 Pa (0.004 cfm/ft2 at 1.57 psf) |
ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | No water penetration at 20 psf pressure differential |
ASTM C518 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | K-Factor of 0.136 BTU.in/hr.ft2. °F at 75°F |
ASTM C1363 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus | K-Factor of 0.12 BTU.in/ hr.ft2. °F at 39°F |
WALL LOAD SPAN TABLES
- PRODUCT: Insulated Wall Panel
- PROFILE: Mesa or Smooth
- SERIES: Edge, Horizon
- GAUGE: 26ga or heavier
- FINISHED: Embossed or Smooth
Panel Thickness | Design Criteria | PSF | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
4' | 5' | 6' | 7' | 8' | 9' | 10' | 11' | 12' | 13' | 14' | ||
2" Thick (See Table Note #3) | Bending/Shear | 93 | 59 | 41 | 30 | 23 | 18 | 15 | 12 | 10 | ||
Deflection (L/180) | 47 | 41 | 33 | 27 | 22 | 19 | 16 | 14 | 12 | |||
Connection | 42 | 35 | 33 | 26 | 22 | 19 | 16 | 15 | 13 | |||
3" Thick | Bending/Shear | 126 | 101 | 84 | 68 | 52 | 41 | 33 | 27 | 23 | ||
Deflection (L/180) | 94 | 77 | 68 | 58 | 34 | 32 | 29 | 19 | 17 | |||
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | |||
4" Thick | Bending/Shear | 168 | 134 | 112 | 84 | 64 | 51 | 41 | 34 | 29 | 24 | 21 |
Deflection (L/180) | 110 | 101 | 92 | 79 | 67 | 57 | 49 | 42 | 37 | 32 | 29 | |
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | 17 | 16 | |
5" Thick | Bending/Shear | 168 | 134 | 112 | 84 | 64 | 51 | 41 | 34 | 29 | 24 | 21 |
Deflection (L/180) | 110 | 101 | 92 | 79 | 67 | 57 | 49 | 42 | 37 | 32 | 29 | |
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | 17 | 16 | |
6" Thick | Bending/Shear | 168 | 134 | 112 | 84 | 64 | 51 | 41 | 34 | 29 | 24 | 21 |
Deflection (L/180) | 110 | 101 | 92 | 79 | 67 | 57 | 49 | 42 | 37 | 32 | 29 | |
Connection | 57 | 45 | 38 | 33 | 29 | 25 | 23 | 20 | 19 | 17 | 16 |
TABLE NOTES:
- Allowable loads were derived from tests conducted in accordance with ASTM E1592 and ASTM E72.
- Allowable loads are calculated with a factor of safety of 2.0 for bending and shear.
- Connection strengths reflect a standard fastener pattern - (@) 1/4” - 14 self drilling screw into minimum 14ga substrate. Other substrates must be designed separately. 2” wall panel utilize a flat clip. All other thicknesses utilize an angle clip.
- Fastener capacity is based on manufacturer pullout/pullover data and are calculated with a safety factor of 3.0.
- Allowable loads assume a minimum bearing of 2”.
- Thermal Effects were not considered in analysis.
- The structural capacity of the supporting members were not considered.
- Bending/Shear and Deflection for 5” and 6” panels based on 4” capacity.
PANEL WEIGHTS & LENGTHS TABLE
- Width: 42”
- Profile: Mesa
- Insulation Thickness: 2”, 3”, 4”, 5”, 6”
- Exterior Facing: 22ga
- Interior Facing: 22ga, 24ga, 26ga
- Available Finish: Emboss, Light Emboss
Panel Weights (PSF)
Panel Thickness (in.) | Panel Width (in.) | PSF | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
26/26 | 24/26 | 22/26 | 26/24 | 24/24 | 22/24 | 26/22 | 24/22 | 22/22 | ||
2 | 42 | 2.23 | 2.48 | 2.73 | 2.48 | 2.73 | 2.98 | 2.73 | 2.98 | 3.23 |
3 | 42 | 2.44 | 2.69 | 2.94 | 2.69 | 2.94 | 3.19 | 2.94 | 3.19 | 3.44 |
4 | 42 | 2.65 | 2.90 | 3.15 | 2.90 | 3.15 | 3.40 | 3.15 | 3.40 | 3.65 |
5 | 42 | 2.85 | 3.10 | 3.35 | 3.10 | 3.35 | 3.60 | 3.35 | 3.60 | 3.85 |
6 | 42 | 3.06 | 3.31 | 3.56 | 3.31 | 3.56 | 3.81 | 3.56 | 3.81 | 4.06 |
Maximum Length based on colour (ft)
Panel Thickness (in.) | Panel Width (in.) | Edge 22ga Wall* | Horizon 26ga/26ga Wall | Skyline 24ga/26ga Roof | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Light | Medium | Dark | Light | Medium | Dark | Light | Medium | Dark | ||
2 | 42 | 25' | 25' | 20' | 38' | 25' | 16' | 47' | 36' | 24' |
3 | 42 | 30' | 30' | 20' | 45' | 35' | 25' | 50' | 38' | 30' |
4 | 42 | 30' | 30' | 25' | 50' | 38' | 28' | 52' | 41' | 32' |
5 | 42 | 32' | 30' | 25' | 52' | 41' | 30' | 52' | 44' | 34' |
6 | 42 | 32' | 30' | 25' | 52' | 44' | 32' | 52' | 47' | 36' |
*Smooth or Embossed
Light = Regal White
Medium = Sierra Tan, Parchment, Silver Metallic
Dark = All others
Based on 5’ support spacing for walls & 4’ support spacing for roofs
*Smooth or Embossed
Subject to change without notice. Please refer to our website, www.ubuildsb.com for current information.
Skyline Roof Panels
Skyline Roof panels are produced with a standard Mesa profiled non-embossed smooth steel face. These roof panels are an economical option for industrial and commercial projects. The 2” Standing seam is mechanically folded and incorporates a hidden fastened clip.
- COVERAGE WIDTH: 42” (1067mm)
- PANEL LENGTHS: 10’ to 52’ (3048mm to 15850mm)
- EXTERIOR FACE: 22ga, 24ga, or 26ga Mesa Smooth galvanized G-90 (Z275) pre painted steel
- INTERIOR FACE: 22ga, 24ga, or 26ga Mesa profile in Smooth or Light Embossed finish galvanized G-90 (Z275) pre painted steel in Regal White. Other colour options are available.
THICKNESS | 2” | 3” | 4” | 5” | 6” |
---|---|---|---|---|---|
R-VALUE* | 16.67 | 25 | 33.33 | 41.67 | 50 |
Standard Colours
Premium Colours
- Colours may not appear exactly as shown above and may vary slightly.
- Please confirm prior to specifying, estimating or ordering.
- Final colour selection should be made from a steel colour sample.
- Colour selection may be subject to availability.
- Custom colours available upon request.
TESTING: INSULATED METAL PANELS
Standard | Description | Results |
---|---|---|
CAN/ULC S101 | Standard Methods of Fire Endurance Tests of Building Construction and Materials | 15-minute stay in place |
CAN/ULC S102 | Standard Method of Test for Surface Burning Characteristics of Building Materials and Assemblies | Flame Spread < 25, Smoke Development < 200 |
CAN/ULC S126 | Standard Method of Test for Fire Spread Under Roof-Deck Assemblies | Complies |
CAN/ULC S127 | Standard Corner Wall Method of Test for Flammability Characteristics of Non-Melting Foam Plastic Building Materials | Flame Spread < 350 foam core w/o steel skin |
CAN/ULC S138 | Standard Method of Test for Fire Growth of Insulated Building Metal Panels in a Full-Scale Room Configuration | Complies |
ASTM E84 | Standard Test Method for Surface Burning Characteristics of Building Materials | Flame Spread < 25, Smoke Development < 200 |
NFPA 286 | Standard Methods of Fire Tests for Evaluating Contribution for Wall and Ceiling Interior Finish to Room Fire Growth | Complies |
ASTM E72 | Standard Test Methods of Conducting Strength Tests of Panels for Building Construction | See Load Charts for load/span and deflection tables |
ASTM E1592 | Standard Test Method for Structural Performance of Sheet Metal Roof and Siding Systems by Uniform Static Air Pressure Difference | See Load Charts |
ASTM E1646 | Standard Test Method for Water Penetration of Exterior Metal Roof Panel Systems | No water penetration at 20 psf pressure differential |
ASTM E1680 | Standard Test Method for Rate of Air Leakage Through Exterior Metal Roof Panel Systems | 0.02 L/(s.m2) at 75 Pa (0.004 cfm/ft2 at 1.57 psf) |
ASTM E283 | Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen | 0.02 L/(s.m2) at 75 Pa (0.004 cfm/ft2 at 1.57 psf) |
ASTM E331 | Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference | No water penetration at 20 psf pressure differential |
ASTM C518 | Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus | K-Factor of 0.136 BTU.in/hr.ft2. °F at 75°F |
ASTM C1363 | Standard Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus | K-Factor of 0.12 BTU.in/ hr.ft2. °F at 39°F |
ROOF LOAD SPAN TABLES
- PRODUCT: Insulated Roof Panel
- PROFILE: Mesa
- SERIES: Skyline
- GAUGE: 26ga or heavier
- FINISHED: Smooth
Panel Thickness | Design Criteria | 2' | 3' | 4' | 5' | 6' | 7' | 8' |
---|---|---|---|---|---|---|---|---|
2" Thick | Bending/Shear | 192 | 128 | 96 | 77 | 64 | 49 | 38 |
Deflection (L/240) | 58 | 53 | 48 | 43 | 36 | 29 | 24 | |
Connection | 65 | 44 | 33 | 26 | 22 | 19 | 16 | |
3" Thick | Bending/Shear | 192 | 128 | 96 | 77 | 64 | 49 | 38 |
Deflection (L/240) | 58 | 53 | 48 | 43 | 36 | 29 | 24 | |
Connection | 65 | 44 | 33 | 26 | 22 | 19 | 16 | |
4" Thick | Bending/Shear | 291 | 224 | 168 | 134 | 112 | 96 | 84 |
Deflection (L/240) | 98 | 95 | 92 | 90 | 76 | 63 | 53 | |
Connection | 65 | 44 | 33 | 26 | 22 | 19 | 16 | |
5" Thick | Bending/Shear | 317 | 286 | 215 | 172 | 143 | 123 | 107 |
Deflection (L/240) | 108 | 102 | 96 | 90 | 83 | 70 | 58 | |
Connection | 65 | 44 | 33 | 26 | 22 | 19 | 16 | |
6" Thick | Bending/Shear | 349 | 312 | 248 | 199 | 166 | 142 | 124 |
Deflection (L/240) | 110 | 110 | 109 | 109 | 108 | 92 | 77 | |
Connection | 65 | 44 | 33 | 26 | 22 | 19 | 16 |